User Manual

Table Of Contents
24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports
Configure System Information User Manual128
7. Select whether to display physical interfaces, LAGs, VLANs, or al by clicking one of the
following links above the table heading:
•1 (the unit ID of the switch). Only physical interfaces are displayed.
This is the default
setting.
VLAN. Only VLANs are displayed.
LAG. Only LAGs are displayed.
All. Physical interfaces, VLANs, and LAGs are displayed.
The following table describes the nonconfigurable data that is displayed.
Field Description
Interface The interface from which the DHCP message is received.
Untrusted Server
Messages With Opt82
The number of DHCP message with option82 received from an untrusted server.
Untrusted Client
Messages With Opt82
The number of DHCP message with option82 received from an untrusted client.
Trusted Server Messages
Without Opt82
The number of DHCP message without option82 received from a trusted server.
Trusted Client Messages
Without Opt82
The number of DHCP message without option82 received from a trusted client.
8. Click the Refresh button to refresh the page with the latest information about the switch.
9. Click the Clear button to reset the statistics.