The Advanced LLDP Configuration screen contains the following fields:
LLDP Properties
• LLDP – Select the LLDP global status on the device. The possible field values are:
– Disable – Disables LLDP on the device. This is the default value.
– Enable – Enables LLDP on the device.
• LLDPDU Handling – Select LLDPDU (LLDP Data Unit) packet handling when LLDP is
disabled. The possible field values are:
– Flooding – LLDPDU packets are flooded to all ports in the system.
– Filtering – LLDPDU packets are filtered. This is the default.
• TLV Advertised Interval – Enter the rate in seconds at which LLDP advertisement
updates are sent. The possible field range is 5 - 32768 seconds. The default value is 30
seconds.
• Topology Change Notification Interval – Displays the amount of time that has elapsed
since the bridge was initialized or reset or the last topology change that occurred. The time
is displayed in a day-hour-minute-second format, such as 2 days 5 hours 10 minutes and 4
seconds.