Configure System Information User Manual79
Configure the green Ethernet EEE LPI history
You can configure and view the Green Ethernet low power idle (LPI) history.
To configure the port Green Ethernet EEE LPI history:
1. Connect your computer to the same network as the switch.
You can use a WiFi or wired connection to connect your computer to the network, or
connect directly to a switch that is off-network using an Ethernet cable.
2. Launch a web browser.
3. In the address field of your web browser, enter the IP address of the switch.
If you do not know the IP address of the switch, see
Change the default IP address of
the switch on page 13.
The login window opens.
4. Enter the switch’s password in the Password field.
The default password is
password.
The System Information page displays.
5. Select System > Management > Green Ethernet > Green Ethernet LPI History.
6. Select the interface.
7. In the Sampling Interval field, enter the interval at which EEE LPI data is collected.
This is a global setting and is applied to all interfaces. The range is 30 to 36000.The
default value is 3600.
Energy Detect Operational Status Current operational status of the Energy Detect mode.
EEE Admin mode Enable or disable Energy Efficient Ethernet mode on the port. With EEE
mode enabled, the port transitions to low power mode during link idle
conditions.
Table 22. Green Ethernet Statistics Summary information (continued)
Field Description