Configure Switching User Manual160
Auto-VoIP is disabled by default.
The Operational Status field displays the current operational status of each interface.
9. Click the Apply button.
Your settings are saved.
Manage the OUI table
Device hardware manufacturers can include an OUI in a network adapter to help identify a
hardware device. The OUI is a unique 24-bit number assigned by the IEEE registration
authority. The switch comes preconfigured with the following OUIs that identify the IP phone
manufacturer:
00:01:E3: SIEMENS
00:03:6B: CISCO1
00:12:43: CISCO2
00:0F:E2: H3C
00:60:B9: NITSUKO
00:D0:1E: PINTEL
00:E0:75: VERILINK
00:E0:BB: 3COM
00:04:0D: AVAYA
1
00:1B:4F: AVAYA2
00:04:13: SNOM
Y
ou can select an existing OUI or add a new OUI and description to identify the IP phones on
the network.
Configure the OUI table
To configure the OUI Table:
1. Connect your computer to the same network as the switch.
You can use a WiFi or wired connection to connect your computer to the network, or
connect directly to a switch that is off-network using an Ethernet cable.
2. Launch a web browser.
3. In the address field of your web browser, enter the IP address of the switch.
If you do not know the IP address of the switch, see
Change the default IP address of the
switch on page 13.
The login window opens.
4. Enter the switch’s password in the Password
field.