10. In the MaxFail field, enter the maximum number of failures allowed in the session.
The default value is 5. The range is 1 to 255.
11. In the Interval (secs) field, enter the time between probes in seconds.
The default value is 3. The range is 1 to 60.
12. In the Port field, enter the UDP destination port for the probe packets.
The default value is 33434. The range is 1–65535.
13. In the Size field, enter the size of the probe packets.
The default value is 0. The range is 32 to 32768.
14. Click the Apply button.
A traceroute request is sent to the specified IP address or host name. The results are
displayed below the configurable data in the Results field.
Enable Remote Diagnostics
You can enable or disable the option to access the switch remotely. When remote access is
enabled, you or technical support can perform remote diagnostics services.
To enable remote diagnostics:
1. Connect your computer to the same network as the switch.
You can use a WiFi or wired connection to connect your computer to the network, or
connect directly to a switch that is off-network using an Ethernet cable.
2. Launch a web browser.
3. In the address field of your web browser
, enter the IP address of the switch.
If you do not know the IP address of the switch, see
Discover or Change the Switch IP
Address on page 12.
Your web browser might display a security message, which you can ignore. For more
information, see Access the Local Browser Interface on page 18.
The login window opens.
4. Enter the switch’
s password in the Password field.
The default password is password.
The System Information page displays.
5. Select Maintenance > T
roubleshooting > Remote Diagnostics.
The Remote Diagnostics page displays.
6. Select the Enable radio button.
7. Click the Apply button.
Your settings are saved.