Configure Quality of Service User Manual179
To configure multiple interfaces with the same settings, select the check box
associated with each interface.
T
o configure all interfaces with the same settings, select the check box in the heading
row.
8. From the Queue ID menu, select the queue to be configured.
You can select a queue from 0 to 7.
9. From the Scheduler T
ype menu, select one of the following options:
Strict.
The interface services traffic with the highest priority on a queue first.
Weighted.
The interface uses weighted round robin to associate a weight to each
queue. This is the default setting.
10. Click the Apply button.
Your settings are saved.
The Queue Management Type field displays the queue depth management technique
that is used for queues on the interface. By default, this method is
Taildrop, irrespective
of your selection from the Scheduler Type menu.
Map 802.1p Priorities to Queues
You can view or change which internal traffic classes are mapped to the 802.1p priority class
values in Ethernet frames that the device receives. The priority-to-traffic class mappings can
be applied globally or per interface. The mapping allows the switch to group various traffic
types (for example, data or voice) based on their latency requirements and give preference to
time-sensitive traffic.
To map 802.1p priorities to queues:
1. Connect your computer to the same network as the switch.
You can use a WiFi or wired connection to connect your computer to the network, or
connect directly to a switch that is of
f-network using an Ethernet cable.
2. Launch a web browser.
3. In the address field of your web browser
, enter the IP address of the switch.
If you do not know the IP address of the switch, see
Discover or Change the Switch IP
Address on page 12.
Your web browser might display a security message, which you can ignore. For more
information, see Access the Local Browser Interface on page 18.
The login window opens.
4. Enter the switch’
s password in the Password field.
The default password is password.
The System Information page displays.