User Manual

Table Of Contents
S350 Series 8-Port Gigabit Ethernet Smart Switch Models GS308T and GS310TP
Configure Switching User Manual171
Your web browser might display a security message, which you can ignore. For more
information, see
Access the Local Browser Interface on page 18.
The login window opens.
4. Enter the switch’s password in the Password
field.
The default password is password.
The System Information page displays.
5. Select Switching > L2 Loop Protection > L2 Loop Protection Configuration.
6. Use one of the following methods to narrow down the ports that are displayed:
To display all the physical ports, click the 1 link.
To display all LAGs only, click the LAG link.
To display all ports and LAGs, click the All
link.
In the Go To Port field, type the port number
, for example g18, and click the Go
button.
7. Select one or more check boxes for to the left of the Port column.
8. From the Keep Alive menu, select Enable or Disable to specify whether keep-alives are
enabled on an interface.
The default is Disable.
9. From the RX Action menu, select the action that occurs when the switch detects a loop on
an interface:
Log.
The switch logs a message.
Disable. The switch disables the interface.
This is the default action.
Both. The switch both logs a message and disables the interface.
10. Click the Apply
button.
Your settings are saved.
11. Click the Clear button to clear all the statistics in the table.
12. Click the Update button to update the page to show the latest information.