User Manual

Table Of Contents
Insight Managed 8-Port Gigabit (Hi-Power) PoE+ Smart Cloud Switch with NETGEAR FlexPoE Power
Perform Maintenance Tasks User Manual393
If you previously added the switch to an Insight network location, enter the Insight
network password.
For more information about the local device password and the Insight network password,
see
Credentials for the local browser UI on page 28.
5. Click the Login button.
The System Information page displays.
6. Select Maintenance > Troubleshooting > Ping IPv6.
The Ping IPv6 page displays.
7. From the Ping menu, select the type of ping:
Global. Pings a global IPv6 address.
Link Local. Pings a link-local IPv6 address over a specified interface. With this
selection, the Interface menu displays, and you must select the interface.
8. In the IPv6 Address/Hostname field, enter the IPv6 address or host name of the station
that must be pinged.
The format is xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx. The maximum number of
characters is 255.
9. In the Count field, enter the number of echo requests that must be sent.
The range is 1 to 15. The default value is 3.
10. In the Interval (secs) field, enter the time in seconds between ping packets.
The range is 1 to 60. The default value is 3.
11. In the Datagram Size field, enter the datagram size.
The valid range is 0 to 13000. The default value is 0 bytes.
12. From the Source menu, select the IP address or interface that must be used to send echo
request packets:
None. The source address of the ping packet is the address of the default egress
interface.
IPv6 Address. The source IP address that must be used when echo request packets
are sent. With this selection, the IPv6 Address field displays and you must enter the
IPv6 address that must be used as the source.
Interface. The interface that must be used when echo request packets are sent. With
this selection, the Interface menu displays and you must select an interface as the
source.
13. Click the Apply button.
The specified address is pinged. The results are displayed below the configurable data in
the Results field.