Quick Start Manual

Installation Guide for the Model EN516 Ethernet Hub
Installation 3-7
Figure 3-4 illustrates multiple hubs cascaded in a daisy-chain style.
Key:
1 = Model EN516 hub with Normal/Uplink push button set to Normal position
2 and 3 = Model EN516 hub with Normal/Uplink push button set to Uplink position
Figure 3-4. Cascading multiple hubs daisy-chain style through the RJ-45 ports
Connecting to the BNC Port
The BNC port at the rear panel of the Model EN516 hub is used for connecting to a thin coaxial
segment. You can connect servers, workstations, or other devices to the BNC port or several Model
EN516 hubs as shown in Figure 3-5. By using the BNC port for cascading, you treat each
connected hub as just another node on the coaxial segment.
When using the BNC interface, follow these steps:
1.
Insert the BNC T-connector on the BNC port of the Model EN516 hub.
2.
Connect the coaxial cable that leads from a device on the network to one of the
self-locking ends of the BNC T-connector.
Note:
Each twisted pair cable between two hubs is counted as one network segment.
When cascading hubs daisy-chain style through the twisted pair cable, stay within
Ethernet specications and make sure the total hub count does not exceed ve hubs.