Quick Start Manual
Installation Guide for the Model EN516 Ethernet Hub
3-6 Installation
Cascading refers to connecting hubs together to increase the number of ports, or the number of 
users supported on the network. The RJ-45, BNC, or AUI ports can be used to cascade hubs 
together. Figure 3-3 illustrates multiple hubs cascaded in a hierarchical star. 
Key:
1 = Model EN516 hub with the Normal/Uplink push button set to Normal position
2 through 7 = Model EN516 hub with the Normal/Uplink push button set to Uplink position
Figure 3-3. Cascading multiple hubs in a hierarchical star through the RJ-45 ports 
Note: 
Ethernet specifications limit the number of hubs in any communication path to five 
hubs, as shown in Figure 3-3. For example, when PC “A” communicates with PC “B,” the 
communication path goes from hub 5 to hub 7, passing through hubs 2, 1, and 4. 
Model EN516 hub Model EN516 hub
Model EN516 hub
30EA
Model EN516 hub Model EN516 hub Model EN516 hub
Model EN516 hub
765
A
432
1