Example:
(M4500-48XF8C) #show rmon hcalarms
Index OID Owner
----- ------------------------- ---------------------------------------------
1 alarmInterval.1 monitorHCAlarm
(M4500-48XF8C) #show rmon hcalarm 1
Alarm 1
----------
OID: alarmInterval.1
Last Sample Value: 5
Interval: 1
Sample Type: absolute
Startup Alarm: rising-falling
Rising Threshold High: 0
Rising Threshold Low: 1
Rising Threshold Status: Positive
Falling Threshold High: 0
Falling Threshold Low
The lower 32 bits of the absolute value for threshold for the sampled statistic. The range
is 0 to 4294967295. The default is 1.
Falling Threshold
Status
This object indicates the sign of the data for the falling threshold, as defined by the
objects hcAlarmFallingThresAbsValueLow and hcAlarmFallingThresAbsValueHigh.
Possible values are valueNotAvailable, valuePositive, or valueNegative. The default is
valuePositive.
Rising Event
The index of the eventEntry that is used when a rising threshold is crossed. The range is
1 to 65535. The default is 1.
Falling Event
The index of the eventEntry that is used when a falling threshold is crossed. The range
is 1 to 65535. The default is 2.
Startup Alarm
Alarm that sent when the entry is enabled. The default is rising-falling.
Owner
The owner string associated with the alarm entry. The default is monitorHCAlarm.