User Manual

Table Of Contents
NETGEAR M4500 Series Switches CLI Command Reference Manual 311
HC Overflow Pkts 65 - 127 Octets: 0 HC Pkts 65 - 127 Octets: 6063
HC Overflow Pkts 128 - 255 Octets: 0 HC Pkts 128 - 255 Octets: 0
HC Overflow Pkts 256 - 511 Octets: 0 HC Pkts 256 - 511 Octets: 0
HC Overflow Pkts 512 - 1023 Octets: 0 HC Pkts 512 - 1023 Octets: 0
HC Overflow Pkts 1024 - 1518 Octets: 0 HC Pkts 1024 - 1518 Octets: 0
5.4.15.7. show rmon hcalarms
This command displays the entries in the RMON high-capacity alarm table.
Format show rmon { hcalarms | hcalarm <index>}
Mode Privileged EXEC
Display Message
Fields
Definition
Index
An arbitrary integer index value used to uniquely identify the high capacity alarm entry.
The range is 1 to 65535.
OID
The object identifier of the particular variable to be sampled. Only variables that resolve
to an ASN.1 primitive type of integer.
Interval
The interval in seconds over which the data is sampled and compared with the rising and
falling thresholds. The range is 1 to 2147483647. The default is 1.
Sample Type
The method of sampling the selected variable and calculating the value to be compared
against the thresholds. Possible types are Absolute Value or Delta Value. The default is
Absolute Value.
Startup Alarm
Rising Threshold High
The upper 32 bits of the absolute value for threshold for the sampled statistic. The range
is 0 to 4294967295. The default is 0.
Rising Threshold Low
The lower 32 bits of the absolute value for threshold for the sampled statistic. The range
is 0 to 4294967295. The default is 1.
Rising Threshold
Status
This object indicates the sign of the data for the rising threshold, as defined by the
objects hcAlarmRisingThresAbsValueLow and hcAlarmRisingThresAbsValueHigh.
Possible values are valueNotAvailable, valuePositive, or valueNegative. The default is
valuePositive.
Falling Threshold
High
The upper 32 bits of the absolute value for threshold for the sampled statistic. The range
is 0 to 4294967295. The default is 0.