User Manual

Table Of Contents
NETGEAR M4500 Series Switches CLI Command Reference Manual 284
5.4.10.15. no sflow poller interval
Use the no sflow poller interval return to default value zero.
Format no sflow poller interval
Mode Interface Config
5.4.10.16. sflow sampler index
Use this command to configure a new sFlow sampler instance on an interface or a range of interfaces for this
data source if the specified receiver is valid. A data source configured to collect flow samples is called a sampler.
Flow samples for the sFlow sampler are sent to the sFlow receiver. Only active receivers can be set. If a receiver
expires, then all samplers associated with the receiver will also expire. The range of <index> is 1-8.
Format sflow sampler <index>
Default None
Mode Interface Config
5.4.10.17. no sflow sampler
Use the no sflow sampler return to default setting.
Format no sflow sampler
Mode Interface Config
5.4.10.18. sflow poller index
A data source configured to collect counter samples is called a poller. Use this command to enable a new sFlow
poller instance on an interface or a range of interfaces for this data source if the specified receiver is valid. The
range of <index> is 1-8, which indicates the sFlow receiver associated with the poller.
Format sflow poller <index>
Default None
Mode Interface Config
5.4.10.19. no sflow poller
Use the no sflow poller return to default setting.