User's Manual
Table Of Contents
- ProSafe Dual Band Wireless N Access Point WNDAP350 Reference Manual
- Contents
- About This Manual
- Chapter 1 Introduction
- Chapter 2 Basic Installation and Configuration
- Wireless Equipment Placement and Range Guidelines
- Understanding WNDAP350 Wireless Security Options
- Installing the WNDAP350 wirelss access point
- Logging In Using the Default IP Address
- Setting Basic IP Options
- Wireless Settings
- Setting Up and Testing Basic Wireless Connectivity
- Understanding Security Profiles
- SSID and WEP/WPA Settings Setup Form
- Configuring the RADIUS Server Settings
- Setting up a Security Profile
- Configuring WEP
- Configuring WPA with RADIUS
- Configuring WPA2 with RADIUS
- Configuring WPA and WPA2 with RADIUS
- Configuring WPA-PSK
- Configuring WPA2-PSK
- Configuring WPA-PSK and WPA2-PSK
- Restricting Wireless Access by MAC Address
- Chapter 3 Management
- Remote Management
- Remote Console
- Upgrading the Wireless Access Point Software
- Configuration File Management
- Changing the Administrator Password
- Enabling the SysLog Server
- Using Activity Log Information
- Viewing General Summary Information
- Viewing Network Traffic Statistics
- Viewing Available Wireless Station Statistics
- Enabling Rogue AP Detection
- Viewing Rogue AP Statistics
- Packet Capture
- Chapter 4 Advanced Configuration
- Chapter 5 Troubleshooting and Debugging
- No lights are lit on the wireless access point.
- The Wireless LAN activity light does not light up.
- The LAN light is not lit.
- I cannot access the Internet or the LAN with a wireless capable computer.
- I cannot connect to the WNDAP350 to configure it.
- When I enter a URL or IP address I get a timeout error.
- Using the Reset Button to Restore Factory Default Settings
- Appendix A Default Settings and Technical Specifications
- Appendix B Related Documents
- Appendix C 2.0 Command Line Reference
- Index
ProSafe Dual Band Wireless N Access Point WNDAP350 Reference Manual
3-4 Management
v2.0, April 2013
To use the CLI from a Console Port:
1. Using the null-modem cable, connect a VT100/ANSI terminal or a workstation to the port
labeled Console.
If you attached a PC, Apple Macintosh, or UNIX workstation, start a secure terminal-
emulation program.
2. Configure the terminal-emulation program to use the following settings:
• Baud rate: 9600 bps
• Data bits: 8
• Parity: none
•Stop bit: 1
• Flow control: none
These settings appear below the connector on the back panel.
3. Press Enter. The screen shown below in Figure 3-3 should appear.
4. Enter the login name and password (admin and password are the defaults).
After successful login, the <Access Point Name> prompt should appear. In this example, the
prompt is netgear74F35E.
5. Enter
help to display the CLI command help.
CLI Commands
The CLI commands are listed in Appendix C, “Command Line Reference.”
Figure 3-3










