User's Manual

100
Vodafone MachineLink 3G
www.netcommwireless.com
Recovery mode
The Vodafone MachineLink 3G features two independent operating systems, each with its own file systems. These two systems are
referred to as 'Main' and 'Recovery'. It is always possible to use one in order to restore the other in the event that one system
becomes damaged or corrupted (such as during a firmware upgrade failure).
Both systems have Web interfaces that can be used to manipulate the other inactive system. The MachineLink 3G starts up by
default in the Main system mode, however the router may be triggered to start in recovery mode if desired.
To start the router in recovery mode:
1. Press and hold the physical reset button on the interface panel of the router for 5 to 15 seconds. When the LEDs on the
front panel change to amber and countdown in a sequence, release the reset button. The router then boots into recovery
mode.
2. In your browser, navigate to
http://192.168.1.1. The router’s recovery mode is hardcoded to use this address regardless
of the IP address that was configured in the main system. The router’s recovery console is displayed.
Figure 100 - Recovery console
The recovery console provides limited functionality. Basic status information is available, as well as access to the System log for
troubleshooting. The Application Installer can be used to upload and install different firmware, allowing you to roll back to a previous
firmware in the event that an upgrade fails. The Settings menu provides the ability to reset the router to factory default settings and
the Reboot tab allows you to perform a soft reboot of the router.