User's Manual

10
Vodafone MachineLink 3G
www.netcommwireless.com
Interfaces
The following interfaces are available on the Vodafone MachineLink 3G:
Figure 3 - Interfaces
ITEM DESCRIPTION
External main antenna socket
SMA female connector for an optional external antenna (not supplied). The main internal
antenna is disabled when an external antenna is connected but the auxiliary antenna
remains active to provide (where possible) diversity assistance.
Power LED Indicates the power status of the device and whether the device is in recovery mode.
Network LED Indicates the network and SIM status.
Signal strength LEDs Indicates the signal strength and network type.
RJ45 PoE Ethernet port
Connect one or several devices via a network switch here. This port can also optionally
receive Power over Ethernet (802.3af PoE) in which case the DC power supply can serve
as backup power source if required.
Reset button
Press and hold for less than 5 seconds to reboot to normal mode.
Press and hold for 5 to 15 seconds to reboot to recovery mode.
Press and hold for 15 to 20 seconds to reset the router to factory default settings.
Two-way captive power
Connect power source here. Power wires may be terminated on optional terminal block
and connected to DC input jack. Operates in the 8-35V DC range.
SIM tray eject Insert a pencil or paper clip here to eject the SIM card tray.
SIM card slot Insert SIM card here.
Table 5 - Interfaces