AT+FACTORY_RESET
Description: Resets the NTC-3000 to factory default settings, effectively performing the following commands:
AT + PAD = 0
AT + APN =
AT + USER_PASS = "",""
AT + FORCE_RESET = 0
AT + SERVER = ,1516
AT + SMS_DIAGNOSTICS= 0
AT + SMS_ACK = 0
AT + SMS_PASSWORD = 1234
AT + EOL = 0x0D,0x0A
AT + SERIAL_BAUD = 115200
AT + SERIAL_FORMAT = 3
AT + SERIAL_PARITY = 4
AT + SERIAL_FLOW = 0
AT + CHAR_TIMEOUT = 8 seconds
AT + TCP_TIMEOUT = 10
AT + TCP_RETRY = 0 (Infinite)
AT + DYN_ENABLE = 0
AT + DYN_HOST =
AT + DYN_USER =
AT + DYN_PASS =
Usage: AT+FACTORY_RESET=1
Help: AT+FACTORY_RESET=?
AT+SERIAL_ON_START
Description: This command configures whether the serial port initialises on power up or initialises when there are active connections.
Usage: AT+SERIAL_ON_START=x
where ‘x’ is an option number
Usage 2: AT+SERIAL_ON_START?
Help: AT+SERIAL_ON_START=?
Options: 1 serial port is initialised on power up
0 serial port is initialised when there are active connections