Chapter 4
4. Installation - Existing Netbiter Argos Account
To add further Netbiter Gateways to an existing Netbiter Argos account, the account must be config-
ured for the Netbiter service Manage & Analyze (M&A). It is not possible to add further gateways to
the View and Control Netbiter service.
If you need to upgrade your account at Netbiter Argos to M&A, please contact your sales contact
to purchase a subscription key. Further information on the actual upgrade process can be found
in the Netbiter Argos Administration Manual.
The following are required for this installation:
• A Netbiter EasyConnect Gateway.
• The printed document with the System ID and Activation Code supplied with the product.
• For a wireless model - a Netbiter SIM card from HMS Industrial Networks, or a SIM card from
another operator.
4.1. Installation Procedure
1. Perform the physical installation of the Netbiter EasyConnect Gateway according to the supplied
documentation. The unit should be powered up before proceeding with the steps below.
2. Log in to the user account at Netbiter Argos.
3. Navigate to Management >> All Systems >> Add system
4. Enter a descriptive name for the new field system
(field system = 1 Netbiter EasyConnect Gateway + connected devices).
5. Enter the System ID and Activation code for the Netbiter EasyConnect Gateway. These are
provided on a printed document supplied with the unit.
6. Select the Project the field system will belong to.
7. Set the Time zone where the field system will be installed.
8. Click the Add button, which adds the field system to the list of Inactive Systems.
9. The system must now be activated, see section 4.2.