Technical Specications
Dimensions 3.8in x 7.7in x 1.6in (9.7cm x 19.6cm x 4.1cm)
Weight 18oz (0.51kg)
Battery Rechargeable lithium-ion battery pack (3.6V, 6Ah, 21Wh)
Battery Life Typical operating life is 4 hours. Typical charge time is 7 hours.
Display 5.0 in color LCD with capacitive touch screen (480 x 800 pixels)
Keypad 1-key elastometric (power only)
Host Interface Micro USB On-the-Go port
USB Port USB 2.0 Type A port
SD Card Slot Supports Micro SD
Cable Test Pair length, crossed, reversed and distance to open, short, split.
Tone Generator Digital tone: [455 KHz]; Analog tones: [400 Hz, 1KHz]
Ports
RJ-45 copper port 10/100/1000BASE-T. 100/1000BASE-X. Fiber adapter port. Fiber
port supports standard SFP.
External AC
Adapter/Charger
AC input 90-264 Vac 48-62 Hz input power DC output 15 Vdc at 2 amps or RJ-45
via PoE
LEDs 2 LEDs (transmit and link indicators)
Environmental Specications
Operating Temperature
32°F to 113°F (0°C to +45°C) NOTE: The battery will not charge if the
internal temperature of the tester is above 122°F (50°C).
Operating Relative Humidity (%
RH without condensation)
90% (50°F to 95°F; 10°C to 35°C) 75% (95°F to 113°F; 35°C to 45°C)
Shock and Vibrations 1 m drop test, Random, 3.8 grms, 5 Hz-500 Hz (Class 2)
Safety IEC 61010-1:2010: Pollution degree 2
Altitude 4,000m; Storage: 12,000m
EMC
IEC 61326-1:2013: Basic Electromagnetic Environment; CISPR 11: Group
1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that
is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to
a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential
diculties in ensuring electromagnetic compatibility in other environments due to conducted and radiated
disturbances.