User Manual
Table Of Contents
- User Manual
- LEGAL NOTIFICATION
- Table of Contents
- List of Figures
- 1. Introduction
- 2. AirCheck G2 Tester Physical Features
- 3. The AirCheck G2 Home Screen
- 4. Discovering Networks and Access Points
- 5. Viewing Channel Usage
- 6. Discovering Clients
- 7. Detecting Interferers
- 8. Using AutoTest to Diagnose Your Network Health
- 9. Conducting a Site Survey Using AirMapper
- 10. Testing Ethernet for Access Point Backhaul
- 11. Companion Services
- 12. Customizing the Tester for your Network
- 13. Verifying Connectivity and Coverage
- 14. Locating an Access Point, Client, or Interferer
- 15. Performing a Network Roaming Test and AP Range Test
- 16. Conducting iPerf Performance Testing
- 17. Saving Test Sessions, Packet Captures, and Screenshots
- 18. Managing Files on the AirCheck G2 Tester
- 19. All AirCheck G2 Settings
- 20. Maintenance
- 21. Specifications and Compliance
- Appendix A: Quick Reference: Examining your Network Health
- How is my Network Quality?
- What is in the Wireless Environment?
- Can Devices Connect to My Network?
- What is Causing Slow Network Performance or Dropped Connections?
- Are There Security Risks in My Network?
- Where is an Access Point?
- What Networks or Access Points Come into Range as I Move?
- How Can I Document My Network and My Test Session?
Specifications and Compliance
129
21. SPECIFICATIONS AND COMPLIANCE
Environmental Specifications
Operating temperature 32ºF to 113ºF (0ºC to +45ºC)
NOTE: The battery
will not charge if the internal temperature of the tester is above 122ºF
(50ºC).
Operating relative humidity
(% RH wit
hout condensation)
90% (50ºF to 95ºF; 10ºC to 35ºC)
75% (95ºF to 113ºF; 35ºC to 45ºC)
Storage temperature -4ºF to 140ºF (-20ºC to +60ºC)
Shock and vibration 1 m drop test, Random, 3.8 grms, 5 Hz-500 Hz (Class 2)
Safety IEC 61010-1:2010: Pollution degree 2
Altitude Operating: 4,000 m; Storage: 12,000 m
EMC IEC 61326-1:2013: Basic Electromagnetic Environment; CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio
frequency energy that is necessary for the internal function of the equipment itself.
Class A: Eq
uipment is suitable for use in all establishments other than domestic and those
directly connected to a low-voltage power supply network that supplies buildings used for
domestic purposes. There may be potential difficulties in ensuring electromagnetic
compatibility in other environments due to conducted and radiated disturbances.