Installation Guide

12 in
(30.5 cm)
BEST
HERE
4 in
(10 cm)
Minimum
4 in
(10 cm)
Minimum
NOT IN
THIS AREA
CEILING
SIDE
WALL
OKAY
HERE
NEST LOGO
IS UPRIGHT
NOT IN
THIS AREA
ANYWHERE IN
THIS AREA
NOT IN
THIS AREA
ANYWHERE IN
THIS AREA
NEST LOGO
IS UPRIGHT
4
in
(10cm)
4
in
(10cm)
3
ft
(0.9 m)
3
ft
(0.9 m)
3
ft
(0.9 m)
Figure 1
Figure 2
Figure 3
Figure 4
White:
Neutral line
Black:
Power line
Bare copper
Red/orange/yellow:
Interconnect
3/8 in (1 cm)
The exposed wire should be straight.
1312
Placement on the ceiling or wall
Installing on the ceiling is recommended.
Mark where the screws will go using the
base as a guide. Make sure it’s at least
4 inches (10 cm) away from the wall.
Placement on a sloped ceiling
If you have a sloped, peaked or cathedral
ceiling, Nest Protect should be 4 inches to
3 feet (10 cm – 1 m) from the highest point.
9. Attach the Nest connector
Hold the white wire ends together, cap them
with a wire nut and twist clockwise until it’s
secure. Do the same with the black wires.
There’s no need for the red/orange/yellow
wire. Simply cap it with a wire nut and twist
until secure.
8. Remove the old connector
Unscrew the wire nuts to detach the 120V
connector from your old smoke alarm.