1. Feed the antenna cable and housing through the 1 ¾” hole in the meter pit lid. Slip the large plastic
nut over the antenna cable and thread it onto the antenna assembly to secure it to the pit lid (Figure
1).
2. Connect the coaxial cable connector to the connector on the transmitter housing (Figure 2).
3. Making sure the washer is properly seated, connect the plastic connector housing to the 3-lobed
black plastic latch-plate (Figure 3).
4. Slide the black conical-shaped gasket down the cable until it engages the connector housing (Figure
4).
5. Tighten the connector nut onto the threaded portion of the connector housing (Figure 5).
6. If desired, use the included cable tie to hang the MIU from the antenna tube (Figure 6).
7. Place the magnet against the side of the MIU in the area shown and swipe it in the indicated direction
to activate the MIU (Figure 7).
Wall MIU Installation
Gel caps should be used to connect the pigtail from the MIU to the register wire.
When using the Scotchlok gel caps, pair the wires according to the color chart in Table 1. With the
ends of the colored wires stripped approximately ¼”, slide the pair into the gel cap as far as they will go.
Then, firmly squeeze the gel cap with an appropriate crimping tool. One gel cap should be used for each
colored wire pair.
(See picture 9.)
Proceed to the section entitled “Installing the MIU.”
Installing the Wall MIU
1. Attach the mounting adapter to the wall using the appropriate holes.
2. Storing the excess wire in the hollow cavity on the back of the MIU, slide the tongue on the top of the
MIU into the groove on the top of the mounting adapter (Figure 10).
3. Secure the MIU to the mounting adapter using the Hi/Lo fastener provided (Figure 11).
4. Place the magnet against the side of the MIU in the area shown and swipe it in the indicated direction
to activate the MIU
(Figure 12).
Note: For best performance in Fixed-Network configuration, wall MIU may be
mounted horizontally.