User's Manual

14
Diagnostics/Error Codes
5.1.6. Meter Errors
The following table contains the meter errors available for display in the diagnostic status word.
Meter Errors Error Codes
Unprogrammed *
1
000001
Configuration Error *
1
000010
Self Check (microprocessor status) *
1
000100
RAM Error *
1
001000
Nonvolatile Memory Error (EEPROM) *
1
010000
Measurement Error *
1
100000
Table 6 - Meter Errors
All diagnostic errors are displayed at the end of the scroll sequence by means of a single six-digit
diagnostic status word prefixed with a *1. The user has the ability to mask each individual error code
from being displayed via the configuration tool. If an error code is displayed, the meter must be master
reset with the FOCUS Configuration Tool software to clear the error.
5.1.7. Power Outage Counter
The user has the ability to read a power outage counter via the configuration tool. The power outage
counter resets following a master reset procedure.