User's Manual
11
4.1.3. Socket base
1). Compare wiring with diagrams of Section 3.2 to make sure the meter is wired properly.
2). Plug meter terminal blades into socket to make a connection with the terminal jaws.
3). Apply load.
4). Check to make sure that the LCD operates and sequences through the display items which were
programmed into the meter.
4.1.4. K-Base
1). Compare the wiring with diagrams of Section 3.2 to made sure the meter is wired properly. Install
bypasses (if change-out).
2). Install the meter on the studs in the K-mounting device.
3). Tighten down nuts securely to torque requirements listed inside the socket. Remove bypasses (if
change-out).
4). Apply load
5). Check to make sure that the LCD operates and sequences through the display items which were
programmed into the meter.