User's Manual
American Models AM-175/250
Index Removal
Complete the following steps for index removal.
1
Use a flathead screwdriver to puncture and remove the tamper plugs, if
present.
2
Use a large screwdriver to remove and discard the four lens mounting screws
and the lens.
3
Remove the gasket.
4
Use a small screwdriver to remove the index mounting screws and the index.
Mounting of Index to R900G Endpoint
Complete the following steps to mount the index to a ROOOG Endpoint.
Carefully mate the drive dog from the index to the drive dog of the ROOOG
Endpoint.
2
Secure the index to the module using the two index screw from Step 4 in the
previous section.
3
Place clear plastic covers over the front of the w1it.
4
Use the four mounting screws that are supplied to attach the entire assembly
to the gas meter main case.
5
Program tile installation.
6
Test tile installation
7 Place new tamper plugs over the screws.
R900G Endpoint Installation and Maintenance Guide
8