Instruction Manual
Table Of Contents
Review
The RESEND key is used to review or re-transmit reads. Each time the Review key is
pressed, a previous read is displayed and re-transmitted.
l Press REVIEW / RESEND to see the previously captured readings. When a low battery
is detected, the following message appears: LOW BATTERY.
l Recharge the battery if you see this message.
l Press REVIEW / RESEND to re-start.
Reading Error
A Reading Error is usually caused by one of these situations:
l End probe not aligned with remote pad.
l No encoder is connected to remote pad.
l Encoder is not connected properly to remote pad.
l Connecting wire is cut or broken.
Other Errors
This section provides information on two other error messages.
l SHORT – Displayed as H; indicates the odometer contains a short circuit. N:I2HH55.
l OPEN – Displayed as a – (dash); indicates odmeter contains an open circuit.
N: I2- - 55.