User Manual
CellNet Pit MIU Master Rev. 1.0
04/14/99 3:13 PM
3
OPERATIONS OVERVIEW
The CellNet-Ready Pit MIU (ProRead Only) collects meter readings from the encoder register on
an hourly basis and transmits the information every fifteen minutes. This redundant transmission
of the same data four times an hour increases the reliability of the data to be received by the fixed
network MCC.
1-4
SPECIFICATIONS
Electrical Specifications
Transmitter Specifications
Environmental Conditions
Encoder Register Interface
Table 1.2 Electrical Specifications
Battery 3.6V D size Lithium
Transmit Period Every 15 min
Register Read Period Once an hour
Table 1.3 Transmitter Specifications
Spread Spectrum Direct Sequence
Carrier Frequency 902-928 MHz
FCC Verification Part 15.247
Table 1.4 Environmental Conditions
Operating Temperature -22° to 149°F (-30° to 65°C)
Storage Temperature -40° to 185°F (-40° to 85°C)
Operating Humidity 0 to 95% Condensing
Table 1.5 Encoder Register Interface
Encoder Register Maximum Cable Length
Schlumberger PRO-READ* 500 feet (152 meters)
* Meets manufacturers’ published specification for wire length between encoder and remote receptacle.
Dimensions and Weight
Table 1.6 Dimensions and Weight
Dimensions Refer to following figures
Weight approximately 2.2 LB (1044 grams)