User Manual
CellNet Pit MIU Master Rev. 1.0
04/14/99 3:13 PM
16
TROUBLESHOOTING
Six-Wheel Encoder Normal Operation
If the odometer reads 123456, the display should be 1 2 3 4 5 5.
Note that the last digit displayed is a five if the last digit on the odometer is five through nine. The
last digit displayed is a zero if the last digit on the odometer is zero through four.
Four-Wheel Encoder Normal Operation
If the odometer reads 123456, the display should be 1 2 3 4 0 0.
Abnormal Operation
Below are examples of abnormal operation for four-wheel encoders. Abnormal operation for six-
wheel encoders is similar except that digits occupy all six positions.
If an (H) or a ( - ) occurs on any of the four positions, the CellNet-Ready Pit MIU (ProRead Only)
will transmit the data as follows:
Examples: 1 2 E 4 0 0 or 1 2 b 4 0 0
If the wire between the CellNet-Ready Pit MIU (ProRead Only) and the encoder is cut or reads as
open, or if the encoder is not programmed in a three-wire TDI format, the MIU will transmit the
following data:
Example: AAAAAA
SECTION 5
TESTING AND MAINTENANCE
After the CellNet-Ready Pit MIU (ProRead Only) has been installed and wired, follow these steps
to verify that the MIU is working properly:
1. Activate the MIU by holding the magnet for two seconds against the arrow on the Main
housing. The arrow is just to the right of the Terminal Screws.
2. Use a CellNet installation tool to verify the transmission from the Pit MIU.
3. Verify all electrical connections.
4. Test the installation again.
5. If a Pro-Read
®
Encoder Register is used, ensure the unit is programmed in the 3-wire, ten digit
TDI format.
6. Verify all electrical connections.
7. Reactivate the MIU. (See Step 1)
8. If a problem still exists, install a different MIU.