User Manual

2
cellnetmiu Rev. 0
12/3/98 4:32 PM
PRODUCT DESCRIPTION
The Wall Meter Interface Unit1(Wall MIU1 or MIU1) by Schlumberger, is a compact
electronic device that collects meter reading data from an encoder register and transmits the
data for collection to a nearby line of sight CellNet MicroCell Controller(MCC) fixed
network. This product is based on CellNet BAMM RF design. This is a one way
transmission to MCC. Since the MIU can be mounted as much as 500 feet from the encoder
register, (See Table 1.5 for system compatible encoders and maximum installation cable
length/distance.), optimum broadcast signal strength is obtainable, insuring a high percentage
of accurate. The MIU also meets FCC regulations part 15.247, allowing higher output power
and greater range. The MIU uses direct sequence spread-spectrum technology to avoid RF
interference and enhance security.
¥ Protects utility liability by increasing meter reader safety.
¥Requires no field programming.
¥ Economizes manhours needed to collect and process meter reading
data, thereby increasing utility profits.
Figure 1.1 Wall MIU
OPERATIONS OVERVIEW
The Wall MIU1 collects meter readings from the encoder register on an hourly basis and
transmits the information every fifteen minutes. This redundant transmit of the same data
four times an hour increases the greater reliability of the data to be received the fixed
network MCC.
1-4
SPECIFICATIONS
Electrical Specifications
Transmitter Specifications
Environmental Conditions
Encoder Register Interface
Table 1.2 Electrical Specifications
Battery 3.6V D size Lithium
Transmit Period Every 15 min
Register Read Period Once an hour
Table 1.3 Transmitter Specifications
Transmitter Channels 1
Channel Frequency 902-928 MHz
FCC Verification Part 15.247
Table 1.4 Environmental Conditions