Abnormal Operation
Below are examples of abnormal operation for four-wheel encoders. Abnormal operation for
six-wheel encoders is similar except that digit occupy all six positions.
A If an (H) or a ( - ) occurs on any of the four positions, the Wall MIU1 will transmit the
data as follows:
Examples: 1 2 E 4 0 0 or 1 2 b 4 0 0
If the wire between the Wall MIU1 and the encoder is cut or reads as open, the Wall MIU1
will transmit the following data:
Example: AAAAAA
For three-wire installation, the problem may be in the register, wiring between register and
receptacle, receptacle pins, or the TU-89 pins. If all pins are clean and the wiring is verified
to be good, replace the register.
Example: H H H H - -For three-wire installation, replace the register.
SECTION 5
TESTING AND MAINTENANCE
After the MIU has been installed and wired, follow these steps to verify that the MIU is
working properly:
1 Activate the MIU by holding the magnet for two seconds against the arrow on the Main
Housing. The arrow is just to the right of the Terminal Screws.
2 Use a CellNet installation tool to verify the transmission from the Wall MIU1.
¥ Verify all electrical connections.
¥ Test the installation again.
5 If a Pro-Read
¨ Encoder Register is used:
¥ Insure the unit is programmed in Ò3-wire mode.Ó
¥ Verify all electrical connections.
¥ Reactivate the MIU. (See Step 1)
6 If a problem still exists, refer to Section 5, ÒTesting And Maintenance.Ó