REPLACING THE BATTERY
Follow these steps to change-out a Wall MIU1Õs
internal Battery:
1 Unscrew the bolt holding the Main Housing to the
Mounting Adapter.
2 Remove the seal wire or seal clip from the Seal
Holes at the bottom of the Main Housing.
3 Punch the Tamper Pin out of the Terminal Screw
Cover.
4 Remove the Terminal Screw Cover.
5 Remove the wires from the Terminal
Screws.
6 Remove the seal wire or seal clip from the
Seal Holes at the bottom of the Main Housing.
7 Using a flat-head screwdriver, gently pry
down the clip on the bottom of the Main
Housing. When the clip clears the tab on the
Mounting Adapter, pull the Main Housing
away from the Mounting Adapter.
8 Remove the Main Housing by lifting it until
it unhinges and comes free from the Mounting
Adapter.
9 Remove the Battery from the Main Housing
by pressing in on the left end of the Battery
until it releases and comes free from the Main Housing.
10 As close to the Battery as possible, cut the battery connection wires one at a time.
11 Use gel-caps to splice the wires from the new Battery to the wires that connected to the
old Battery.
12 Snap the Battery into the Receiving Clips on the Main Housing.
13 Install the Main Housing on the Mounting Adapter.
14 Install the appropriate color wires to each Terminal Screw (Black to B, Green to G, Red to
R).
15 Follow the steps in ÒTesting the Installation.Ó
Note: Cutting the battery connection wires one at a time prevents shorting.
Note: Insure the Wall MIU1Õs black wire is connected to ground (-) and the red wire is
connected to the positive (+) wires of the new battery.