Maintenance Guide

l Clear the selected location of all obstructions.
l Avoid installing the CMIU behind metal fences or walls.
The maximum cable length between the encoder register and CMIU depends on the
register's manufacturer and model. See the following table for the maximum cable lengths.
Encoder Register Maximum Cable Lengths
Neptune ARB V. Meets manufacturer's published
specification for wire length to the encoder.
300 feet (91 meters)
Neptune ProRead™ / E-CODER
®
500 feet (152 meters)
Sensus Protocol registers 200 feet (61 meters)
Table 7 – Maximum Cable Lengths
Installing the CMIU
This section defines the procedure to install the wall CMIU.
Removing the Main Housing
Complete the following steps to install the wall CMIU.
1. Remove the main housing from the adapter.
Figure 12 – CMIU Main Housing
The Hi-Lo fastener for securing the main CMIU housing to the adapter plate is shipped
separately.
Cellular MIU (CMIU™) Pit and Wall Installation and Maintenance Guide 15
Chapter 4: Wall Installation