General Installation Guidelines
4 CMIU Installation and Maintenance Guide
Safety and Preliminary Checks
Observe the following safety and preliminary checks before and during
each installation.
Verify that you are at the location specified on the site work order.
Verify that the site is safe for you and your equipment.
Notify the customer of your presence and tell the customer that you
need access to the water meter.
Write in the ID number(s) of the MIU you are about to install, if the
site work order does not have an MIU ID number.
Verify that the ID number(s) matches the ID number(s) on the MIU
you are about to install, if the site worker already has an MIU ID
number.
Verifying/Preparing the Encoder Register
The CMIU is designed for use with the following encoder registers:
ARB V
ProRead
ProRead AutoDetect
•E-Coder
Competitive registers using Sensus which include: Sensus ECRII,
ICE, iPerl, OMNI and electronic register; also Hersey/Mueller
Translator, Badger ADE, and HR E|LCD.
Before installing an MIU, the encoder register must be correctly wired
and/or programmed to work with the MIU. E-Coder registers do not
require programming.
Table 2 Recommended Materials
Item Description/Recommendation Use
Cable Solid 3 conductor #22 AWG (black/
green/red) Part # 6431-352
Connect MIU to encoder
register.
Moisture Protection
Compound
Novaguard sealant
Part # 96018-072
Cover exposed wires
and terminal screws on
register and MIU.
Scotchloks Part # 8138-125 Connect wall MIU or
replacement pit MIU to
encoder register.
Site Work Order Documentation provided by your
utility
Receive and record
information about the
work site.