User Manual
Table Of Contents
General Installation Guidelines
4 CMIU Installation and Maintenance Guide
Safety and Preliminary Checks
Observe the following safety and preliminary checks before and during
each installation.
• Verify that you are at the location specified on the site work order.
• Verify that the site is safe for you and your equipment.
• Notify the customer of your presence and tell the customer that you
need access to the water meter.
• Write in the ID number(s) of the MIU you are about to install, if the
site work order does not have an MIU ID number.
• Verify that the ID number(s) matches the ID number(s) on the MIU
you are about to install, if the site worker already has an MIU ID
number.
Verifying/Preparing the Encoder Register
The CMIU is designed for use with the following encoder registers:
• ARB V
• ProRead
• ProRead AutoDetect
•E-Coder
• Competitive registers using Sensus which include: Sensus ECRII,
ICE, iPerl, OMNI and electronic register; also Hersey/Mueller
Translator, Badger ADE, and HR E|LCD.
Before installing an MIU, the encoder register must be correctly wired
and/or programmed to work with the MIU. E-Coder registers do not
require programming.
Table 2 Recommended Materials
Item Description/Recommendation Use
Cable Solid 3 conductor #22 AWG (black/
green/red) Part # 6431-352
Connect MIU to encoder
register.
Moisture Protection
Compound
Novaguard sealant
Part # 96018-072
Cover exposed wires
and terminal screws on
register and MIU.
Scotchloks Part # 8138-125 Connect wall MIU or
replacement pit MIU to
encoder register.
Site Work Order Documentation provided by your
utility
Receive and record
information about the
work site.