User Manual

Table Of Contents
Using the Field Programmer
N_SIGHT R900 User’s Manual for the Neptune Handheld System 8-11
4 For Connectivity, touch one of the following.
Coil – if you are using the touchpad
2W – (2-wi
re) i
f you are using the alligator clip
5 For Dial Code, touch one
of t
he following to adjust
the number of meter read-
ing digits returned from
the register
to a reading
device:
•49
•59
•6
5
otr – to cho
ose
another value from a
selection list. See
Figu
re 8.10. (To return
to the screen from this
list,
select None.)
Figure 8.10 Otr Selection List
6In Register ID, type the ID or serial number of the register.
7 For Cus Char, enter the additio
nal information you want to have
for that meter, such as size or location.
M N L
(upper case, alphanumeric)
1 2 S (numeric digits.)
The water utility often requires modification so that a reading matches its standard
billing units, such as 1000s of gallons.