Instructions

GB
- 16 -
11. Troubleshooting guide
Faults Cause Remedy
The equipment
does not start
- Power supply not connected - Check power supply
The equipment
does not pump
- Intake sieve clogged
- Discharge hose kinked
- Clean intake sieve with water jet
- Unkink the hose
Insu cient pumping
rate
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Clean intake sieve
- Clean equipment and replace wear
parts
The equipment swit-
ches o after brie y
running
- Motor circuit-breaker switches the
equipment o due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment o
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
Anl_NTP-E_100_SPK7.indb 16Anl_NTP-E_100_SPK7.indb 16 16.10.2020 11:50:2416.10.2020 11:50:24