Users Manual

2. Logger Status
2.1 Check Indicator light
Implication Lights Status Description(All lights are single green lights.)
Communication
with router
Communication
with inverter
Logger running
status
1.Light off: Connection to the router failed.
2.On 1s/Off 1s(Slow flash): Connection to the router succeeded.
3.Light keeps on: Connection to the server succeeded.
4.On 100ms/Off 100ms(Fast flash): Distributing network fast.
1.Light keeps on: Logger connected to the inverter.
2.Light off: Connection to the inverter failed.
3.On 1s/Off 1s(Slow flash): Communicating with inverter.
1.Light off: Running abnormally.
2.On 1s/Off 1s (Slow flash): Running normally.
3.On 100ms/Off 100ms(Fast flash): Restore factory settings.
NET
COM
READY
The normal operation status of the stick logger, when router connected
to the network normally:
1.Connection to the server succeeded: NET light keeps on after the
logger powered on.
2.Logger running normally: READY light flashes.
3.Connection to the inverter succeeded: COM light keeps on.
3. Abnormal State Processing
If the data on platform is abnormal when the stick logger is running,
please check the table below and according to the status of indicator
lights to complete a simple troubleshooting. If it still can not be resol-
ved or indicator lights status do not show in the table below, please
contact Customer Support.
(Note: Please using the following table query after power-on for 2mins
at least.)