User's Guide

neo.cortec
.
Page 4 of 10
Document version 1.4
3.3 RF parameters
Parameters Min Typ Max Unit Condition
Receiver
Receiver sensitivity -94
-93
dBm 868MHz 1% packet loss
915MHz 1% packet loss
Saturation -16 dBm
Spurious emissions
25 MHz - 1 GHz
Above 1 GHz
-57
-47
dBm
dBm
Conducted measurement in a 50 Ω single
ended load. Complies with EN 300 328,
EN 300 220 class 2, FCC CFR47, Part 15
and ARIB STD-T-66.
Transmitter
Output power, highest setting +10 dBm Delivered to a 50 Ω single-ended load via
U.FL connector
Output power, lowest setting -30 dBm Delivered to a 50 Ω single-ended load via
U.FL connector
Harmonics radiated
2nd harmonic, 868MHz
3rd harmonic, 868MHz
-55
-54
dBm @+10dBm output power.
Note antenna characteristics can inuence
these gures
Harmonics conducted
868MHz
915MHz
-35
-34
dBm @+10dBm output power
Frequencies above 1GHz
Frequencies above 1GHz
Spurious emissions radiated
Harmonics excluded
868MHz:
Below 1GHz
Above 1GHz
Frequecies between:
47 - 74
87.5 - 118
174 - 230
470 - 862
915MHz:
Below 1GHz
Above 1GHz
-56
-54
-56
-56
-56
-56
-51
-60
dBm +10 dBm output power, measured on CW
output.
Table 5: RF, receive and transmit parameters