UNI DISPENSERS User Manual MODEL UNI-2, UNI-3 10950, 10951
UNI Dispensers Complete Pump 9851(Natural Dome) Complete Pump 9855(Black Dome) Natural Dome 7299 Black Dome 8215 Pump Housing 9720 Dome Clip 7868 Valve 9683 Brush 7615 Designed for use with standard 1½ ,1 or 3/4 gallon pouched condiments and toppings. Pumps attach to 16mm fitments in pouches.
Safety All components must be cleaned before first use. According to food and safety regulations, most foods must be stored and/or served at certain temperatures or they could become hazardous. Check with local food and safety regulators for specific guidelines. Be aware of the product you are serving and the temperature the product is required to maintain. IMPORTANT Clean, rinse, sanitize, and dry parts at a minimum of every 24 hours. Always comply with local sanitization requirements.
Assembly 1 2 3 4 Mount the nozzle onto the end of the pump housing. Bend the outer portion of the nozzle inside out. Insert into opening. Tab of nozzle faces towards housing. Flip the outer portion of the nozzle over the end of tube. Insert dome into the pump housing. Ensure the flaps slide into place. Press the entire dome firmly, including the top portion. Insert the dome clip over the dome and pump housing. Ensure that the tab on bottom of the dome slides into the opening in the dome clip.
4 Insert valve into the bottom of the pump housing. Wrap the flaps on the side of valve onto the pair of pegs on the pump housing. TIP: Lubricate parts with clean water to ease fitting. 5 6 Connect pump to pouch Put new pouch on countertop with fitment facing up. Place piercing end of connector in center of the fitment. Push firmly until pump snaps into place. Hold pouch up and push dome to prime pump. Insert pouch and pump into the dispenser shroud.
7 8 Insert the lid Hold the lever up while inserting lid tabs into slots in back of dispenser shroud. Prime pump Press the pump lever several times until food is visible in discharge tube. Tips & Troubleshooting Product not dispensing? Make sure dome is primed properly. Prevent leaks: Ensure that dome is pushed fully into pump housing. Ensure that you hear a CLICK when attaching pump to pouch. Pro Tip: Clean water may be used as lubrication when fitting valve onto pump housing.
Setting the Portion Remove locking washer 1 Use a flathead screwdriver to pry off the locking washer from the pin at the end of the link arms. Keep locking washer for step 4. Remove pin 2 3 Slide the pin out from the pair of link arms and handle holes. Link Arm Position C B A 2 3 4 1 Select portion setting Portion Portion (fl. oz.) (ml) Handle Position 1.75 1.33 1.00 0.75 0.66 0.50 0.25 0.25 0.03 52.0 39.0 30.0 22.5 19.5 15.0 7.5 7.5 1.
ASEPT General Warranty Liability for defects Should the products, as delivered, within one (1) year from delivery be shown to be defective due to defaults in material or manufacturing (“Warranty Period”), the Supplier undertakes, at its own option (i) to make a replacement delivery, (ii) to repair or rework the products claimed to be defective or (iii) to accept return of such product and refund such proportion of the purchase sum received as corresponds to the returned products.