Installation Instruction
Table Of Contents
- Ceiling-mounted ventilation system
- en
- Table of contents
- 1 Safety
- 2 Preventing material damage
- 3 Environmental protection and saving energy
- 4 Operating modes
- 5 Familiarising yourself with your appliance
- 6 Before using for the first time
- 7 Basic operation
- 7.1 Switching on the appliance
- 7.2 Switching off the appliance
- 7.3 Selecting a fan setting
- 7.4 Switching on intensive mode
- 7.5 Switching off intensive mode
- 7.6 Switching on the fan run-on
- 7.7 Switching off the fan run-on
- 7.8 Switch on automatic mode
- 7.9 Switch off automatic mode
- 7.10 Intermittent ventilation
- 7.11 Sensor control
- 7.12 Setting the sensor control
- 7.13 Resetting the saturation indicator
- 7.14 Setting the saturation indicator
- 7.15 Switching on the lighting
- 7.16 Switching off the lighting
- 7.17 Setting the brightness
- 7.18 Switching on the button tone
- 7.19 Switching the button tone off
- 8 Home Connect
- 8.1 Automatically connecting the appliance to the WLAN home network (Wi-Fi)
- 8.2 Manually connecting the appliance to the WLAN home network (Wi-Fi)
- 8.3 Connecting the appliance to the Home Connect app
- 8.4 Home Connect settings
- 8.5 Software update
- 8.6 Resetting the connection
- 8.7 Remote diagnostics
- 8.8 Data protection
- 9 Hob-based hood control
- 10 Cleaning and servicing
- 10.1 Cleaning products
- 10.2 Cleaning the stainless steel surfaces
- 10.3 Cleaning painted surfaces
- 10.4 Cleaning aluminium
- 10.5 Cleaning plastic
- 10.6 Cleaning glass
- 10.7 Cleaning controls
- 10.8 Removing the grease filter
- 10.9 Cleaning grease filters in the dishwasher
- 10.10 Cleaning grease filters manually
- 10.11 Fitting grease filters
- 10.12 Odour filter for recirculating air mode
- 10.13 Replacing the batteries in the remote control
- 11 Troubleshooting
- 12 Customer Service
- 13 Accessories
- 14 Disposal
- 15 Declaration of Conformity
- 16 Installation instructions
Basic operation en
7
7.5 Switching off intensive mode
▶
To select a fan setting of your choice, press .
a After approx. 6 minutes, the appliance automatically
switches to fan setting 3.
7.6 Switching on the fan run-on
During the fan run-on, the appliance continues to run
for a short time and then switches off automatically.
The fan run-on removes remaining odours and is used
to dry the odour filter after the cooking process.
▶
Press .
a LED1 for the fan setting lights up in the LED dis-
play. LED6 flashes for the fan run-on.
a The appliance switches off automatically after ap-
prox. 10 minutes.
7.7 Switching off the fan run-on
▶
Press .
a This immediately stops the fan run-on.
a The appliance switches to the fan setting that was
previously selected.
7.8 Switch on automatic mode
1
The optimum fan setting is set automatically using a
sensor.
▶
Press .
a In the LED display, LED6 lights up for automatic
mode.
7.9 Switch off automatic mode
1
▶
Press .
a The appliance switches to the fan setting that was
previously set.
a The ventilation is automatically ended when the
sensor detects no further change in the room air
quality.
a Automatic mode runs for a maximum of four hours.
7.10 Intermittent ventilation
With interval ventilation, the ventilation system switches
on and off in the selected setting for the selected time.
Note:This function is only available via a mobile device
with the HomeConnect app.
If the interval ventilation is switched on, LED6 continu-
ously flashes in the LED display for the interval ventila-
tion and the LED for the selected fan setting lights up.
As soon as the ventilation time ends, the LED for the
fan setting you have selected goes out. LED6 contin-
ues to flash.
7.11 Sensor control
In automatic mode, a sensor in the appliance detects
the intensity of the cooking and roasting fumes. De-
pending on the setting of the sensor sensitivity, the op-
timum fan setting automatically switched on.
If the sensor control system reacts too weakly or too
strongly, the setting for the sensor sensitivity may
change.
¡ Default setting: Fan setting3
¡ Lowest setting: Fan setting1
¡ Highest setting: Fan setting5
7.12 Setting the sensor control
Requirement:The appliance is switched off.
1.
Press and hold and for approx.three seconds.
2.
Press or to change the setting.
To cancel the setting, press .
3.
To save the setting, press and hold and for ap-
prox. threeseconds.
Or wait approx. 10seconds until the setting is
saved automatically.
a A signal tone sounds as soon as the selected set-
ting is saved.
7.13 Resetting the saturation indicator
After cleaning the grease filter or after changing the
odour filter, the saturation indicator can be reset.
Requirements
¡ After the appliance has been switched off, LED1
flashes in the LED display for the grease filter satura-
tion display and/or LED2 flashes for the saturation
indicator for the odour filter.
¡ A repeated signal tone sounds.
▶
Press .
a The saturation indicator is reset.
7.14 Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement:The appliance is switched off.
1.
Press and hold and for approx.three seconds.
‒ To set circulating-air mode (non-regenerable fil-
ter), press / until LED2 lights up in the LED
display.
‒ To set circulating-air mode (non-regenerable fil-
ter), press / until LED3 lights up in the LED
display.
‒ To convert the electronic control back to opera-
tion without the air recirculation filter, press /
until LED1 lights up on the LED display.
2.
To save the setting, press and hold and for ap-
prox. three seconds.
Or wait approx. 10seconds until the setting is
saved automatically.
To cancel the setting, press .
a A signal tone sounds as soon as the selected set-
ting is saved.
1
Depending on the appliance specifications