Installation Instruction
Table Of Contents
- [en] Instructions for installation and use
- Ú Table of contents
- [en] Instructions for installation and use
- ( Important safety information
- Important safety information
- : Warning
- : Warning
- Danger of death!
- Risk of poisoning from flue gases that are drawn back in.
- Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as room air- dependent heat-producing appliance is being operated.
- Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coal- operated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air t...
- In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied. Toxic gases from the chimney or the extraction shaft are sucked ...
- Safe operation is possible only when the partial vacuum in the place where the heat- producing appliance is installed does not exceed 4 Pa (0.04 mbar). This can be achieved when the air needed for combustion is able to enter through openings that can...
- In any case, consult your responsible Master Chimney Sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you.
- Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating-air mode.
- : Warning
- : Warning
- : Warning
- : Warning
- : Warning
- : Warning
- Causes of damage
- 7 Environmental protection
- Ç Operating modes
- 1 Operating the appliance
- 2 Cleaning and maintenance
- Cleaning and maintenance
- : Warning
- : Warning
- : Warning
- : Warning
- : Warning
- Cleaning agents
- Removing metal grease filter
- 1. Open the glass front slowly and fully. Hold the glass front in the centre when doing so, gripping it firmly.
- 2. Open the lock and swing down the metal grease filter. When you do this, take hold of the metal grease filter from underneath with your other hand.
- 3. Take the metal grease filter out of the holder.
- Notes
- Cleaning the metal mesh grease filters
- : Warning
- Installing the metal mesh grease filter
- : Warning
- 3 Trouble shooting
- 4 Customer service
- Customer service
- To book an engineer visit and product advice
- Accessories
- ( Important safety information
- Important safety information
- : Warning
- : Warning
- : Warning
- Danger of death!
- Risk of poisoning from flue gases that are drawn back in.
- Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as room air- dependent heat-producing appliance is being operated.
- Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coal- operated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air t...
- In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied. Toxic gases from the chimney or the extraction shaft are sucked ...
- Safe operation is possible only when the partial vacuum in the place where the heat- producing appliance is installed does not exceed 4 Pa (0.04 mbar). This can be achieved when the air needed for combustion is able to enter through openings that can...
- In any case, consult your responsible Master Chimney Sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you.
- Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating-air mode.
- : Warning
- : Warning
- : Warning
- : Warning
- : Warning
- : Warning
- K General information
- 5 Installation
- Installation
- Preparing for installation
- Installation
- Wall-mounting the appliance and levelling it
- 1. First remove the protective film from the back of the appliance and, following installation, remove the rest of the film.
- 2. When mounting the appliance, ensure that it engages properly with the mounting supports.
- 3. If required, the appliance can be moved to the right or to the left.
- 4. Firmly tighten the screws for the mounting supports. Hold the bracket firmly when doing so. ¨
- 5. If no duct is to be fitted, screw in the two locking screws without the bracket. ©
- Connecting the pipes
- Attaching the flue duct
- : Warning
- : Warning
- Risk of electric shock!
- Components inside the appliance may have sharp edges. These may damage the connecting cable. Do not kink or pinch the connecting cable during installation.
- 1. Separate the flue duct sections by removing the adhesive tape.
- 2. Remove the pieces of protective film from both flue duct sections.
- 3. Push one flue duct section into the other.
- Notes
- 4. Place flue ducts sections on the appliance.
- 5. Slide the inner flue duct section upwards, attach it to the left and right sides of the retaining bracket, and then slide it down to engage it. ¨
- 6. Screw the flue duct section to the sides of the retaining bracket using two screws. ©
- 7. Clip the lower flue duct section in at the retaining bracket. The connection cable must not be damaged. ª
- Note:
Installation en
15
5Installation
Instal l ati on
Preparing for installation
Caution!
Ensure that there are no electrical wires, gas pipes or
water pipes in the area where holes are to be drilled.
If the extractor hood is to be operated in exhaust-air
mode, a flue duct must be fitted.
If the extractor hood is to be operated in air-recirculation
mode, an optional accessory must be fitted. To do this,
refer to the installation instructions provided. The flue
duct does not need to be fitted for air-recirculation
mode.
1. Determine where the extractor hood should be
positioned and lightly mark where the lower edge of
the appliance should be on the wall. Determine
where the middle should be based on the hob.
Note: We recommend fitting the extractor hood such
that the lower edge of the glass screen is in line with
the lower edges of the adjacent wall-hung cabinets.
Make sure that the specified safety clearances from
the hob are complied with.
2. Place the template against the line drawn on the wall
and fasten it in place. Mark where the screws should
be inserted.
To fit the flue duct, the template must be cut along
the marked cut line.
3. Drill 8 mm diameter holes to a depth of 80 mm for
fastening the appliance, remove the template and
press in the wall plugs flush with the wall.
$
%
]
]
[
PP
[
PP
[
PP
[
PP
\
\