- Ú Table of contents[en] Instruction manual
- : Important safety information
- Read these instructions carefully. Only then will you be able to operate your appliance safely and correctly. Retain the instruction manual and installation instructions for future use or for subsequent owners.
- The appliance can only be used safely if it is correctly installed according to the safety instructions. The installer is responsible for ensuring that the appliance works perfectly at its installation location.
- This appliance is intended for domestic use and the household environment only. The appliance is not intended for use outside. Do not leave the appliance unattended during operation. The manufacturer is not liable for damage which is caused by improp...
- This appliance is intended for use up to a maximum height of 2000 metres above sea level.
- This appliance may be used by children over the age of 8 years old and by persons with reduced physical, sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are instructed by a person responsi...
- Children must not play with, on, or around the appliance. Children must not clean the appliance or carry out general maintenance unless they are at least 8 years old and are being supervised.
- Keep children below the age of 8 years old at a safe distance from the appliance and power cable.
- Check the appliance for damage after unpacking it. Do not connect the appliance if it has been damaged in transport.
- This appliance is not intended for operation with an external clock timer or a remote control.
- Danger of suffocation!
- Danger of death!
- Risk of poisoning from flue gases that are drawn back in.
- Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as room air-dependent heat-producing appliance is being operated.
- Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coal- operated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air t...
- In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied. Toxic gases from the chimney or the extraction shaft are sucked ...
- Safe operation is possible only when the partial vacuum in the place where the heat- producing appliance is installed does not exceed 4 Pa (0.04 mbar). This can be achieved when the air needed for combustion is able to enter through openings that can...
- In any case, consult your responsible Master Chimney Sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you.
- Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating-air mode.
- Risk of fire!
- Risk of burns!
- Risk of injury!
- Risk of electric shock!
- Environmental protection
- Operating modes
- Operating the appliance
- Cleaning and maintenance
- : Risk of burns!
- : Risk of electric shock!
- : Risk of electric shock!
- : Risk of injury!
- Cleaning agents
- Removing the fleece grease filter
- Fitting the fleece grease filter
- Changing the activated charcoal filter (only in circulating-air mode)
- Notes
- Note
- 1. Remove the fleece grease filter; see the Removing the fleece grease filter section.
- 2. Undo the threaded joint on the activated charcoal filter cover.
- 3. Remove the activated charcoal filter.
- 4. Insert the activated charcoal filter.
- 5. Screw the cover in place.
- 6. Fit the fleece grease filter; see the Fitting the fleece grease filter section.
- Trouble shooting
- After-sales service
- Accessories
6
Environmental protection
Your new appliance is particularly energy-efficient. Here you
can find tips on how to save even more energy when using the
appliance, and how to dispose of your appliance properly.
Saving energy
■ During cooking, ensure that there is a sufficient supply of air
so that the extractor hood can work efficiently and with a low
level of operating noise.
■ Adjust the fan speed to the intensity of the cooking fumes.
Only use intensive mode where this is required. A lower fan
speed means that less energy is consumed.
■ If there are intensive cooking fumes, select a higher fan
speed in good time. If cooking fumes have already spread in
the kitchen, the extractor hood must be operated for longer.
■ Switch off the extractor hood if you no longer require it.
■ Switch off the lighting if you no longer require it.
■ Clean and, if required, replace the filter at regular intervals in
order to increase the effectiveness of the ventilation system
and to prevent the risk of fire.
Environmentally-friendly disposal
Dispose of packaging in an environmentally-friendly manner.
Operating modes
This appliance can be used in exhaust-air mode or circulating-
air mode.
Exhaust air mode
Note: The exhaust air must not be conveyed into a functioning
smoke or exhaust gas flue or into a shaft which is used to
ventilate installation rooms which contain heat-producing
appliances.
■ Before conveying the exhaust air into a non-functioning
smoke or exhaust gas flue, obtain the consent of the heating
engineer responsible.
■ If the exhaust air is conveyed through the outer wall, a
telescopic wall box should be used.
Circulating-air mode
Note: To bind odours in circulating-air mode, you must install
an activated carbon filter. The different options for operating the
appliance in circulating-air mode can be found in the brochure.
Alternatively, ask your dealer. The required accessories are
available from specialist outlets, from customer service or from
the Online Shop. The accessory numbers can be found at the
end of the instructions for use.
This appliance is labelled in accordance with
European Directive 2012/19/EU concerning used
electrical and electronic appliances (waste
electrical and electronic equipment - WEEE). The
guideline determines the framework for the return
and recycling of used appliances as applicable
throughout the EU.
The air which is drawn in is cleaned by the
grease filters and conveyed to the exterior
by a pipe system.
The air which is drawn in is cleaned by the
grease filters and an activated carbon filter and
conveyed back into the kitchen.