User Manual

Invexs 190 readers
© Nedap N.V.
Invexs 190 readers
Install Manual
Page 3 of
4
LED INDICATORS FRONT
At the front a three colour LED is positioned at the middle of the Invexs
Depending of the used configuration the function of these LEDs can differ:
Green LED: Card is been authorised (UL led)
Red LED: Card is not authorised (NA led), controller is stand-by
Blue LED:
Blinks fast: No configuration is availabele at this Invexs (present Configuration
card or load Configuration first).
Continuously ON: Determined by configuration: E.g. Reader stand-by.
(Blue LED is activated if UL is OFF and NA is more than 1 sec OFF)
Remark: Function of LEDs and Beeper is controlled by used application settings of Invexs.
FIRMWARE
Pay attention that the firmware loaded in the Invexs together with the Invexs type and configuration
determines functionality and protocols.
Default (from factory) the Invexs handles the credentials on several ways simultaneously:
Mifare cards (CSN) as: RS485NR, RF data
Remark: The Invexs 190 requires dedicated firmware (not identical to the Invexs 170 firmware)
SYSTEM CONFIGURATIONS (how to connect Invexs readers)
Remark: Configurations can be determined by the AEreco (loaded by AEmon or configuration card).
BEEPER INDICATIONS
Beeper is also used for indication of loading the configuration:
High sound beep (‘happy sound’): Configuration is loaded correct, second high sound beep
indicates that this configuration can be used with this Invexs
Low sound beep (‘unhappy sound’): Configuration is not correct loaded or no configuration
available at startup
To AP4x03 readers with RS485 special encrypted
protocol. (LED’s, Beeper, Keys and Display are
controlled over the RS485 communication)
AEOS RS485 interface