Led Color Status Explanation
2 Blue
Blinking There is device connected to the OUT port of this unitno
On There is a Power Inserter connected to the OUT port of this unit
3 Red
On
There is an issue with the power supply at the OUT port of this unit (too little
current drawn)
Blinking
There is an issue with the power supply at the OUT port of this unit (too much
current drawn)
Off There is issue with the power supply at the OUT port of this unitno
4 Yellow
Blinking The operating system on the Renos unit is running
Off The operating system on the Renos unit is runningnot
5 Green
Blinking The storage flash on the Renos unit is accessed
Off The storage flash on the Renos unit is accessednot
6 Green
On The firmware on the Renos unit is running
Off The firmware on the Renos unit is (yet) runningnot
Please refer to the Troubleshooting chapter later in this manual to resolve erroneous conditions.
Firmware error
If the Renos unit has a firmware error, the rightmost three LEDs (4, 5 and 6) will remain off when the
unit is powered. This can be solved by using a 'Local - single unit' firmware update, as is described