Page of 16 59 Manual iSense Lumen series
3. However, the maximum cable length requirements needs to be satisfied. If it is not possible to put all
the gates within a role in one system due to the maximum cable length requirements, you can split the
gates into two or more systems. In this case assign each system a different duringmulti-system channel
the RF configuration.
Stock room to sales floor and goods receiving
For the stock room to sales floor and goods receiving roles: when there is a different door or
entrance, build a separate system.
Maximum system size
The table below shows the maximum system size for the diffent gates and tops in our product line
for different store positions.
Role / store position Product Max. system size
EAS
RF Gates 100
Hybrid RF/RFID 30
RFID gates 30
RFID tops 30
Stockroom / Salesfloor
RFID gates 2
RFID tops 1
Goods receiving
RFID gates 2
RFID tops 1
It is not possible to combine gates with RFID and without RFID in one system. Either all gates should