8-6 Troubleshooting
On-screen error message Action
8450 Can't Read FRU on CPU Unit Type I Mezzanine Power off and reboot the CPU blade.
Also make sure the mezzanine card is
correctly installed in Type I mezzanine
card slot.
If the error persists, contact your service
representative.
8451 Can't Read FRU on CPU Unit Type II Mezzanine Power off and reboot the CPU blade.
Also make sure the mezzanine card is
correctly installed in Type II mezzanine
card slot.
If the error persists, contact your service
representative.
Expansion Rom not initialize
Run the BIOS SETUP utility to disable
the use of expansion ROM area and PCI
slot OptionROM. If the error persists,
contact your service representative.
Invalid System Configuration Data Contact your service representative.
Resource Conflict
System Configuration Data Read error
System Configuration Data Write error
WARNING: IRQ not configured
IMPORTANT: The message "Expansion Rom not initialized" may be
displayed due to insufficient expansion ROM area. Select one of the
features of the lowest frequency and set it to "Disabled".
– On board LAN 1/On board LAN 2
– PCI slot 1