User manual
CHAPTER 2 SYSTEM CONFIGURATION
Page 42 NEAX 2000 IPS General Description
NDA-24345, Issue 3
• The MP card of Remote Site has the same system data as that of Main Site, because Remote
Site automatically gets the data from Main Site when Remote Site starts. In normal operation,
Main Site automatically copies the system data to Remote Site through the network at the
time set by CM43 Y=7 once a day.
• This feature is available in the Retrofit System (used as Main Site). The system that using the
following MP cards can be mixed used in Remote PIM over IP system in any combination.
Main Site: PN-CP24-A/PN-CP24-B, PN-CP27-A, PN-CP26-A, PN-CP28-A
Remote Site: PN-CP31-B, PN-CP24-A/PN-CP24-B, PN-CP27-A, PN-CP26-A, PNCP28-A
NOTE: PN-CP27-A/PN-CP28-A cannot be used as Backup CPU system in Remote Site.
• This feature is not compatible with Fusion service of 2400 IPX.
• The RUN lamp of Remote Sites’ MP card flash at 60 IPM in normal mode and 120 IPM in
survival mode.
Conditions for System Configuration
• The number of Remote Sites is a maximum of 15.
• The total number of FP/AP at Main Site and all Remote Sites should not exceed 64 including
the MP built-in FP, Virtual FP, and Virtual IPT.
• The number of FP/AP accommodated at one Remote Site should be a maximum of eight
including the MP built-in FP.
• Remote Site can accommodate the following FP/AP/LT cards.
- FP: One MP built-in FP and two Virtual FP
- AP: BRT, 24DTI, 24PRT (ISDN-PRI)
- LT: 8IPLA, DLC, LC, COT, ODT
NOTE: Attendant Console, Desk Console, Add-On Module, DSS/BLF Console are not mountable
at Remote Site.
• Remote Site cannot accommodate the following FP/AP/LT cards.
- FP: FP card (CP15/CP19) is not mountable at Remote Site.
- AP: AP00 (SMDR), AP00 (DBM), ICH, CCH, DCH (ISDN/Q-SIG/Q931a), 4RSTB
(MFC/T1-ANI/E911), 4RSTC/D (Caller ID trunk), CS00 (ATI), CFTC (32-party
conference), IPT
- LT: 8RSTA/G (PBR), ILC (ISDN Terminal), 4RSTE/F (Caller ID station), CFTA/B
(6/10-party conference), AMP, 4VCT, DK00, DAT
NOTE: Four-line built-in PBR on the MP card is available at Remote Site.
• When Remote Site is IPSDMR, in addition to the above conditions, the following LT cards
are restricted.
- PN-4LDTA (LDT), PN-4LLCB (LLC), PN-8PFTB (PFT)
• MP built-in FP must be set to each Remote Site.
• 128 ports are assigned per FP card/MP built-in FP in initial, but the port allocation for FP
card/MP built-in FP can be changed by the programming (CM05 Y=3). The port for FP
card/MP built-in FP must be assigned with every 8 port. If the assignment value cannot be
divided by 8, the value that the remainder is omitted is assigned to the FP card/MP built-in
FP automatically.