Operation Manual
36. SCREEN WIPER Set 
Function 
The external control equipment sets the SCREEN WIPER of the plasma 
monitor. 
Transmission Data 
  DFH 80H 60H C8H 04H DATA00 to DATA03 CKS 
  DATA00 : SCREEN WIPER  00H : No operation 
    01H : ON   
    02H : OFF   
  DATA01 : WORKING TIME  00H : ON 
  01H: 03M (minutes) 
  02H: 06M (minutes) 
   : 
  FFH: 12H (hours) and 45M (minutes) 
  DATA02 : WAITING TIME  01H: 03M (minutes) 
    02H: 06M (minutes) 
   : 
    FFH: 12H (hours) and 45M (minutes) 
  DATA03 : SPEED  01H : 1 
   : 
    05H : 5 
ACK 
  3FH 60H 80H C8H 00H  CKS 
NOTE: The WORKING TIME and the WAITING TIME can be set in
units of 3 minutes. 
Example: 03H=9 minutes 
 1EH=1 hour and 30 minutes 
 31