Operation Manual
27. PHASE Gain Data 
Function 
The external control equipment changes the PHASE gain data (Phase) of the 
plasma monitor. 
Transmission Data 
  DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS 
  DATA00 : USER PICTURE Gain Flag    03H 
  DATA01 : PHASE Gain Flag      03H 
  DATA02 : PHASE Gain       00H : 0 
     : 
   2CH : +44 
ACK 
  7FH 60H 80H 7FH 02H DATA00 DATA01 CKS 
  DATA00: USER PICTURE Gain Flag    03H 
  DATA01: PHASE Gain Flag            03H 
28. CLOCK Gain Data   
Function 
The external control equipment changes the CLOCK gain data (ratio of 
frequency division) of the plasma monitor. 
Transmission Data 
  DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS 
  DATA00 : USER PICTURE Gain Flag    03H 
  DATA01 : CLOCK Gain Flag      04H 
  DATA02 : CLOCK Gain       C0H : -64 
       : 
   FFH : -01 
   00H : 0 
   01H : +01 
     : 
   40H : +64 
ACK 
  7FH 60H 80H 7FH 02H DATA00 DATA01 CKS 
  DATA00: USER PICTURE Gain Flag    03H 
  DATA01: CLOCK Gain Flag            04H 
 26