15. GREEN Gain Data 
Function 
The external control equipment changes the GREEN Gain Data of the plasma 
monitor. 
Transmission Data 
  DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS 
  DATA00 : USER PICTURE Gain Flag    01H 
  DATA01 : GREEN Gain Flag      02H 
  DATA02 : GREEN Gain1(Bias)     D8H : -40 
       : 
   FFH : -01 
   00H : 0 
   01H : +01 
     : 
   1EH : +30 
  DATA03: GREEN Gain2(Drive)     D8H : -40 
       : 
   FFH : -01 
   00H : 0 
   01H : +01 
    : 
   1EH : +30 
ACK 
  7FH 60H 80H 7FH 02H DATA00 DATA01 CKS 
  DATA00: USER PICTURE Gain Flag    01H 
  DATA01: GREEN Gain Flag      02H 
 18