Operation Manual
04. VOLUME Gain Data 
Function 
The external control equipment changes the VOLUME gain data of the plasma 
monitor. 
Transmission Data 
  DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS 
  DATA00: USER SOUND Gain Flag    05H 
  DATA01: VOLUME Gain Flag      01H 
  DATA02: VOLUME Gain      00H: Step0 
       : 
   0AH: Step10 (Default) 
     : 
  2AH: Step42 
ACK 
  7FH 60H 80H 7FH 02H DATA00 DATA01 CKS 
  DATA00: USER SOUND Gain Flag      05H 
  DATA01: VOLUME Gain Flag    01H 
05. AUDIO Mute ON 
Function 
The external control equipment switches on AUDIO Mute of the plasma 
monitor. 
Transmission Data 
  9FH 80H 60H 3EH 00H CKS 
ACK 
  3FH 60H 80H 3EH 00H CKS 
06. AUDIO Mute OFF 
Function 
The external control equipment switches off AUDIO Mute of the plasma 
monitor. 
Transmission Data 
  9FH 80H 60H 3FH 00H CKS 
ACK 
  3FH 60H 80H 3FH 00H CKS 
 12